Browse all practice questions for the Arizona Contractor License – Low Voltage Communication Systems (CR-67) Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Arizona Contractor License – Low Voltage Communication Systems (CR-67) Practice Exam course image
Caring for network cables: why raceways around finished grade matter for broadband setupsNetwork-powered broadband communications cables attached to the building structure should be protected by raceway if located within how many feet of finished grade?Class 3 Conductors Carry Signals in Low-Voltage SystemsWhich of the following describes Class 3 conductors?Jamming too many conductors into a raceway can damage cables in low‑voltage systemsWhat is the implication of jamming when pulling too many conductors into a raceway?Understanding why fusible-type primary protectors are forbidden in Arizona’s low voltage systemsWhich of the following statements is true regarding fuseluse-type primary protectors?What is a ground fault and why it matters for low voltage communication systemsWhat type of fault occurs when electrical current unintentionally flows to the ground?When does electricity flow in a circuit? It’s all about a complete pathUnder what condition may electricity flow?Where to identify the branch-circuit overcurrent protective device for fire alarm equipmentWhere must the branch-circuit overcurrent protective device for fire alarm equipment be identified?Why aerial communications conductors are recommended to be not grounded or interruptedWhat type of protection is recommended for aerial communications conductors?Why medium-power broadband cables should be kept separate from high-voltage wiring in low voltage installationsShould medium-power network-powered broadband communications cables share pathways with high-voltage cables?
More practice questions

These questions are part of the practice quiz. Start practicing

  • What type of protection is necessary for aerial network-powered broadband communications conductors?
  • Can Class 2 and Class 3 conductors be run together?
  • What is the requirement for open conductors according to OSHA?
  • How long should an unlisted outside plant cable be limited to, in feet?
  • How should raceways or bushings that enter a building be positioned?
  • In what configuration should communications wires and cables be kept below?
  • When installing a DC system, is a grounding electrode system with a grounding electrode conductor required?
  • Does NEC require that Class 2 and Class 3 circuits be installed in a raceway?
  • How is thermal resistivity important in low voltage communication systems?
  • What color should the identification of the fire alarm circuit disconnecting means be?
  • A Class 1, Division 1 location is characterized by what?
  • What type of cable should be used for installations in ducts for environmental air?
  • What is the minimum separation distance between network-powered broadband communications cable and any lightning conductors?
  • What acts as the demarcation point for voice, data, and video communications?
  • What identifying feature is required for circuit disconnecting means in fire alarm systems?
  • For both power-limited and non-power-limited circuits, what can be used to protect against electrical surges?
  • Can cable tray systems be used in hoist ways, according to OSHA regulations?
  • What term refers to an unintentional mess up in electrical systems?
  • Can branch circuits supplying fire alarm equipment be used to supply other loads?
  • What is the primary purpose of surge protective devices in low voltage communication systems?
  • A separately derived system may refer to which of the following?
  • What is the maximum allowed power for a power-limited Class 1 source?
  • What is a common use for Class 3 circuits in low voltage systems?
  • What type of conduit offers less protection but is easier to work with?
  • When using a dry cell battery as a power source for a Class 2 system, what must the voltage be?
  • In what units is thermal resistivity typically expressed?
  • Does the insulation type determine where cables can be used?
  • What is the maximum earth resistivity in ohmmeters for an area to be exempt from lightning exposure?
  • What is the minimum receptacle rating that should be used in kitchens where portable appliances will be deployed, even in a low voltage configuration?
  • Is it necessary to gather all drawings prior to performing any electrical installations, according to federal law?
  • What requirement applies to multiconductor cable exposed to direct sunlight according to OSHA?
  • Are Class 1 circuit conductors typically allowed to be tapped?
  • What is the maximum rated output for Class 1 Power-Limited Circuits?
  • True or False: PVC conduit can hold many wires.
  • What is true about fast-blow fuses?
  • Which statement is incorrect regarding Class 1 circuits?
  • What is a reason for constructing effective Ground-Fault current paths?
  • What is the primary material used in the construction of EMT conduit?
  • What specific characteristic defines the insulation of THWN wires?
  • What is the key safety consideration for Class 3 circuits in low voltage communication?
  • What is the first action you should take when someone has suffered an electric shock?
  • What is the required rating for a service disconnect?
  • A flexible cord of 2 or more conductors may be treated as a single conductor for the purpose of?
  • The fire alarm circuit disconnect should have what feature?
  • What is the minimum rating for overcurrent protection on a 16 AWG conductor?
  • Where should a primary protector be located in relation to where the cable enters the building?
  • Can circuits of 40A be used for fixed lighting with heavy-duty lamp holders in cooking appliances?
  • What must be true for a Class 1 enclosure?
  • Which of the following is true regarding RHW-2 wires?
  • Which of the following statements about plastic splice cases is true?
  • What type of cable is acceptable for conducting power-supply and fire alarm circuits together?
  • Is the live wire always ungrounded?
  • Does the amount of bond required in Arizona depend on the type of license and experience?
  • What type of cables are suitable for installation in vertical riser shafts without conduit?
  • To operate Class 2 conductors, what is required?
  • For appliance branch circuits supplying more than one appliance, what is the minimum conductor size for a low voltage configuration?
  • In laundries, what is the minimum receptacle rating required for deploying portable appliances in a low voltage configuration?
  • What should be done if Class 2 cables are found to be abandoned?
  • Are circuits of 30A permitted to serve fixed lighting units with heavy-duty lamp holders in non-dwelling units?
  • Which of the following is NOT characteristic of Class 1 circuits?
  • Which of the following best describes Class 1 circuits?
  • Which type of cables should be used for medium-power network-powered broadband communication circuits located outside a building?
  • Is it true that a GFCI is sensitive to small leaks of current?
  • In an assembled cable with jacketing, insulation for each individual conductor must be rated for at least _____ volts.
  • In which scenario is primary electrical protection required on network-powered broadband communications conductors?
  • True or False: Hot water pipes may be used as grounding electrodes for the protectors.
  • How is the frequency of Alternating Current (AC) measured?
  • Why should solid conductors be avoided for flexible connections?
  • Which article specifically covers premises-powered broadband communications systems?
  • Which of the following statements is correct about conductor sizing?
  • Where should communications wires and cables be located in relation to electric light or power conductors?
  • What is the minimum distance recommended between communications wires and lighting conductors?
  • What key factor differentiates Class 2 circuits from Class 1 circuits?
  • What must be ensured when installing Class 1 circuits with adjacent power supply circuits?
  • Which aspect is important for ensuring safety in installations using FPL cables?
  • What measures the heat transfer capability through a substance by conduction?
  • Cables installed in building locations for environmental air that are not in plenums may be what type?
  • At what height should communication cables maintain clearance above the points they pass?
  • What is an effective Ground-Fault current path?
  • What is the correct definition of a power-limited circuit?
  • Can Class 2 and Class 3 circuits share a cable tray?
  • What occurs if communications wires are attached to a cross-arm carrying electrical conductors?
  • True or False: Hot water pipes may be used as grounding electrodes for the protectors.
  • What is the minimum conductor size for a low voltage configuration?
  • Before cable conductors are terminated, they must first be tested for what?
  • What is the voltage measured between any two line conductors of a balanced three-phase system?
  • What type of conduit is circular and made of metal?
  • Should medium-power network-powered broadband communications cables be allowed to stay in the same cable tray with Class 2 and Class 3 remote-control circuits?
  • Can cables and conductors of Class 2 circuits be placed in a cable compartment with conductors of non-power-limited fire alarm circuits?
  • What is a characteristic of a Class 1 enclosure?
  • What is a characteristic of liquid-tight flexible metal conduit (LFMC)?
  • A lighting system with an isolating power supply must operate at _____ volts peak to be considered low voltage.
  • What kind of current does a Ground Fault Circuit Interrupter respond to?
  • What is the minimum size of conductors that should be used in multi-conductor cables?
  • What is the purpose of a bonding jumper in a broadband communications system?
  • How does an isolating power supply prevent danger in electrical systems?
  • What is the maximum voltage limit for Class 1 signaling and remote control circuits?
  • What is the maximum voltage that audio systems can reach?
  • What type of cable compartment should not include Class 3 circuits?
  • What is the maximum voltage for telephone systems with a ringer?
  • What does Imax refer to in low voltage communication systems?
  • According to OSHA, bare conductors should not be used for which type of circuits?
  • Can Class 2 and Class 3 circuits be installed with Class 1, non-power-limited fire alarm circuits?
  • What does the term 'raceway' refer to?
  • Class 2 equipment is often called what?
  • What type of cables are suitable for installation in environmental air plenum spaces without the need for conduit?
  • Which device converts optical signals into component signals such as voice, audio, video, and data?
  • Are bends in network broadband cable ever allowed?
  • How do watts compare to voltage?
  • A ground electrode conductor originates at what location in the service panel?
  • According to OSHA, what is the minimum size for single conductors used as equipment grounding conductors?
  • What is the purpose of overcurrent protection in fire alarm systems?
  • Which type of wires use rubber insulation but are suitable for wet locations?
  • Cables and conductors of Class 3 circuits should be placed with which type of circuits?
  • What defines a Class 2, Division 2 location?
  • Which of the following best describes the usage of metal boxes with conduit?
  • What is the maximum peak optical density allowed for a low smoke-producing cable?
  • What type of protection is required for underground network-powered broadband communications conductors?
  • Remote-control circuits for safety-control equipment are considered Class _____ if failure to operate poses direct fire or life hazards.
  • An area experiencing how many thunderstorm days or less per year is exempt from lightning exposure concerns?
  • What does CL2 and CL3 classify in low voltage communication systems?
  • What should be marked on the fire alarm control panel?
  • How many years of verifiable experience is required for the C12 license in Arizona?
  • What is the maximum voltage that a Class 1 Remote-Control and Signaling Circuit should never exceed?
  • Article 720 covers circuits and equipment that operate at what voltage or less?
  • What is the highest acceptable voltage limit for Class 1 circuits?
  • Can only plastic splice cases be used as enclosures for terminating telephone cables?
  • Standard lampholders with a rating less than what wattage should not be used for a low voltage configuration?
  • Secondary protectors should be used on circuits exposed to potential contact with electric conductors above what voltage?
  • When pulling three conductors cables into a raceway, jamming may occur when the ratio of the inside diameter of the raceway to the outside diameter of the cable is in the range of?
  • Metal conduit can technically act in place of what?
  • What is the minimum vertical clearance for communications cables at the roof?
  • Which of the following statements regarding branch circuits for fire alarm systems is true?
  • What does the breaking capacity of a fuse specify?
  • What is the maximum allowable overcurrent protection in amperes for 18 AWG conductors?
  • What type of receptacles should be used in electrical installations according to OSHA?
  • What defines the maximum capabilities of a Class 1 Remote-Control circuit?
  • What type of cables can be used inside walls, ceilings, or under the floor?
  • Which conduit type is typically used for emergency lighting circuits?
  • What is commonly used to protect circuits from ground faults?
  • The term "ampacity" is important primarily for which reason?
  • What is the primary characteristic of Class 2 conductors?
  • When installing surge protective devices, which NEC article must be followed?
  • What is one of the key installation requirements for Class 2 circuits?
  • Is it true that a Class 3 circuit considers safety from a fire initiation standpoint?
  • Are copper conductors the only type that can be used for fire alarm systems?
  • Which type of conduit is often used for installations requiring flexibility in tight spaces?
  • Which wiring method is typically required for Class 3 circuits?
  • Only which type of terminal boxes should be used for splicing telephone cables?
  • What happens when the cable bend radius exceeds specifications for broadband cables?
  • In which scenario can Class 1 circuits share a cable with power supply circuits?
  • What is the maximum amperage for overcurrent protection on 16 AWG conductors?
  • What type of cables is recommended for low-power network-powered broadband communication circuits outside of a building?
  • When must the construction of a Main Distribution Frame (MDF) be completed?
  • What is a key requirement for cables designed to produce low smoke?
  • You should size conductors no less than which percentage of the continuous loads plus what percentage of the non-continuous loads?
  • Does Alternating Current (AC) always flow one way then the other?
  • Who administers the licensing in Arizona?
  • What does THWN stand for?
  • What is the proper installation method for communications wires entering a building with a primary protector?
  • Under what condition should communications wires not be attached to a cross-arm?
  • What wiring methods must be used when mixing Class 2 conductors with Class 3 conductors?
  • Conductor sizes are often expressed in which format?
  • Which class of circuits considers safety mainly from a fire initiation standpoint?
  • An insulated grounded conductor which is what gauge or below should be identified by a continuous white or gray outer finish?
  • How should cables and conductors of Class 2 and Class 3 circuits be placed with respect to electric light conductors?
  • How should an interbuilding circuit be protected in areas prone to lightning exposure?
  • What is the minimum size for single conductors in fire alarm systems?
  • What must all communication cable bundles utilize when penetrating rated walls?
  • Which class of circuit permits a higher voltage than a Class 2 circuit?
  • What does VAmax refer to in low voltage communication systems?
  • Can FPL cables be used for general purpose alarms without conduit? If yes, are there any exceptions?
  • What does it mean for circuits to be functionally associated?
  • Should overcurrent devices generally be interchangeable with devices of higher ratings?
  • Under what condition can Class 1 circuits occupy the same cable?
  • What is the minimum separation in inches required between supply service drops of max 750 volts and communications service drops?
  • In the context of communications wiring, what does “service loop” refer to?
  • What serves as the area of demarcation between intra-building and inter-building cabling?
  • What is the minimum overhead span height for network-powered broadband communications cables above the sidewalk?
  • What type of equipment is typical for Class 2 circuits?
  • What term refers to the ability of a voltage to convey information?
  • What should be done with any accessible portion of abandoned Class 2 cables?
  • A Class 1 Circuit is defined as being between which two points?
  • What does amplitude refer to in electrical signals?
  • Which type of cables are most appropriate for damp areas?
  • Under what condition can Class 1 circuits and power-supply circuits be in the same raceway?
  • What type of grounding is required for a supply transformer of a 50V or lower system when sourced over 150V to ground?
  • What is Class 1, Division 1 equipment commonly referred to as?
  • What is the maximum pulling tension in pounds allowed for copper wire?
  • Which of the following describes a Class 2, Division 1 location?
  • Should a ground electrode be in contact with the earth?
  • Are fuseluse-type primary protectors allowed?
  • What is the smallest wire size permitted on a Class 1 circuit?
  • What is the return path for electrical power to flow back to the service panel?
  • What is a short circuit?
  • What is Imax in the context of low voltage communication systems?
  • Which of the following is NOT a valid type of conduit?
  • What is the maximum allowed amperage for overcurrent protection on 18 AWG conductors in fire alarm systems?
  • What type of conductors are preferred for making terminations, splices, or taps within a raceway?
  • Is it acceptable to use a junction box for encapsulating a 120V AC wire connection to a 12-24V DC power converter?
  • Which of the following is NOT considered in low voltage system installations?
  • How many wall switch-controlled lighting outlets are required in every habitable room?
  • What is the minimum headroom required in a typical workspace for a working voltage under 600V?
  • What is the primary function of an Intermediate Distribution Frame (IDF)?
  • What effect can accidental contact with underground wiring have when digging?
  • True or False: Direct-buried cables that are emerging from the ground must be protected by enclosures or other means.
  • Which device extends the community antenna television system from the service provider to the customer equipment?
  • What is the minimum gauge for bonding conductors used with primary protectors?
  • Concerning fire alarm systems, the overcurrent protection should not exceed ______ amperes for 16 AWG conductors.
  • What is a characteristic of flexible conduit?
  • Why should network-powered broadband cables be installed in hollow spaces?
  • What protection level must Class 1 Power Sources have from overcurrent devices?
  • What should support cables in a low voltage configuration?
  • What is required for communication cable bundles when they pass through fire-rated walls?
  • What is the voltage limitation for Class 2 circuits?
  • Voltage drop can be calculated using which of the following formulas?
  • A Class _____ Circuit operates between the load side of a Class 2 power source and connected equipment.
  • A bonding jumper at least ______ AWG copper in size should be used to connect the network-powered broadband communications system grounding electrode with the power grounding electrode system.
  • What is true regarding Class 2 circuits and transformers?
  • What refers to the allowable current-carrying capacity of a conductor?
  • What is required for Class 1 circuit conductors and power-supply conductors that are not functionally associated?
  • Which voltage measurement is primarily associated with the line side of a three-phase system?
  • How many hot wires typically run from the utility company into the service panel?
  • What type of conduit is described as a metal thin-walled conduit?
  • What is true about the conductors of power-supply and fire alarm circuits when placed in the same cable?
  • A cable that is fire resistant should exhibit a maximum flame spread distance of no more than how many feet?
  • What is the maximum nominal output voltage for non-power limited fire alarm circuits?
  • A Class 2 circuit can have a maximum voltage of which of the following?
  • To ensure safety, Class 2 circuits should avoid risks of what?
  • Does grounding and bonding mean the same thing?
  • What is the maximum flame spread distance for fire-resistant cables?
  • Is it true that Class 2 circuits must be kept separate from lighting?
  • Is placing power cords or wires under carpets or rugs considered safe practice?
  • Which standard outlines the requirements for Class 2 and Class 3 conductors?
  • When a circuit poses a direct life safety hazard, it must be classified as what?
  • What voltage rating do secondary protectors need to be compatible with when used on circuits exposed to electric light conductors?
  • What size AWG copper bonding jumper should be used to connect the network-powered broadband communications system grounding electrode with the power grounding electrode system?
  • True or False: You do not need to provide primary electrical protection for network-powered broadband communications conductors that are not exposed to lightning.
  • What type of wires use rubber insulation that is high heat resistant and is only suitable for dry locations?
  • What describes the voltage measured across any one component of a balanced three-phase system?
  • Should direct-buried network-powered broadband communications cables be separated from conductors of any non-power limited fire alarm circuits?
  • Which type of wire is often used in residential wiring applications?
  • Are Class 1 Remote-Control and Signaling Circuits required to have limited power output?
Subscribe